Control of hypoxia using apneic oxygenation with extrapulmonary membrane elimination of CO2

Skorik, V.I.; Malikova, T.M.; Boltovskaia, L.F.; Zelikson, B.M.; Safonova, E.S.

Biulleten' Eksperimental'noi Biologii i Meditsiny 104(8): 162-164

1987


ISSN/ISBN: 0365-9615
PMID: 3620670
Document Number: 296959
The peculiarities and conditions of optimal gas exchange for arresting hypoxia during prolonged (3 hours) apnoea or bradypnoea were experimentally studied in 34 dogs, using the method of apnoea oxygenation and extrapulmonary membrane removal of CO2 on "Sever" membrane gas-exchanger. It was shown that successful arrest of severe ventilation disorders of respiration by this method depends on precise registration and skillful use of the factors influencing oxygenation and CO2 removal in membrane gas-exchanger connected with peripheral arteriovenous or venovenous shunts.

Document emailed within 1 workday