Replenishment of Young-GIK cardioplegia under the re-aortic cross clamp
Takeuchi, E.; Murase, M.; Tanaka, M.; Hibi, M.; Yasuura, K.; Ogawa, K.; Hotta, A.; Saigusa, H.; Yoshida, K.; Abe, T.
Nihon Kyobu Geka Gakkai 34(4): 447-452
1986
ISSN/ISBN: 0369-4739 PMID: 3734502 Document Number: 284362
Document emailed within 1 workday
Related Documents
Kirshner, R.L.; Geary, J.E.; Welch, E.L. 1986: Acute aortic rupture from cross clamp injury Journal of Cardiovascular Surgery 27(2): 185-187Kyösola, K.; Chambers, D.; Canković-Darracott, S.; Braimbridge, M.V. 1987: Long-term survival rates after prolonged aortic cross-clamping with St. Thomas' Hospital cardioplegia Annales Chirurgiae et Gynaecologiae 76(4): 241-242
Rosenkranz, E.R.; Okamoto, F.; Buckberg, G.D.; Robertson, J.M.; Vinten-Johansen, J.; Bugyi, H.I. 1986: Safety of prolonged aortic clamping with blood cardioplegia. III. Aspartate enrichment of glutamate-blood cardioplegia in energy-depleted hearts after ischemic and reperfusion injury Journal of Thoracic and Cardiovascular Surgery 91(3): 428-435
Shimizu, Y.; Miyamoto, T.; Ozawa, M.; Ohashi, H.; Oka, Y.; Tomita, E.; Maeda, S.; Ogawa, N.; Yoshida, T. 1982: Injury to ascending aorta by aortic clamp during operation for the thoracic aortic aneurysm Nihon Kyobu Geka Gakkai 30(10): 1730-1738
Sugimura, S.; Kakihara, R.; Katsuragawa, K.; Okamoto, K.; Watanabe, K. 1980: A case of acute ascending aortic dissection from aortic clamp injury Nihon Kyobu Geka Gakkai 28(3): 470-473
Assar, A.N.; Zarins, C.K. 2009: Endovascular proximal control of ruptured abdominal aortic aneurysms: the internal aortic clamp Journal of Cardiovascular Surgery 50(3): 381-385
Yasuura, K.; Okamoto, H.; Ogawa, Y.; Matsuura, A.; Asakura, T.; Seki, A.; Hoshino, M.; Maseki, T.; Sawazaki, M.; Itoh, T. 1994: Resection of aortic aneurysms without aortic clamp technique with the aid of hypothermic total body retrograde perfusion Journal of Thoracic and Cardiovascular Surgery 107(5): 1237-1243
Fitzgerald, P.A.; Brady, M.P.; Keaveny, T.V. 1974: A technique for application of the infrarenal aortic clamp during resection and graft replacement of an abdominal aortic aneurysm Surgery Gynecology and Obstetrics 138(2): 251
Pehkonen, E.J.; Anttonen, O.M.; Tarkka, M.R. 1994: Blood and crystalloid cardioplegia in aortic valve surgery Annales Chirurgiae et Gynaecologiae 83(4): 292-295
Hashimoto, R.; Matsuzawa, H.; Matsukawa, T.; Yokozawa, T.; Ohzeki, H.; Oguma, F.; Nakagome, M.; Eguchi, S. 1983: Local cardiac hypothermia with or without cardioplegia in aortic valve surgery Kyobu Geka. Japanese Journal of Thoracic Surgery 36(12): 953-957
Shiki, K. 1986: A comparative study between blood and crystalloid cardioplegia during prolonged aortic occlusion in dogs Nihon Kyobu Geka Gakkai 34(11): 1954-1965
Robertson, J.M.; Vinten-Johansen, J.; Buckberg, G.D.; Rosenkranz, E.R.; Maloney, J.V. 1984: Safety of prolonged aortic clamping with blood cardioplegia. I. Glutamate enrichment in normal hearts Journal of Thoracic and Cardiovascular Surgery 88(3): 395-401
Liebold, A.; Langhammer, T.h.; Brünger, F.; Birnbaum, D.E. 1999: Cardiac interleukin-6 release and myocardial recovery after aortic crossclamping. Crystalloid versus blood cardioplegia Journal of Cardiovascular Surgery 40(5): 633-636
Pearl, J.M.; Laks, H.; Drinkwater, D.C.; Meneshian, A.; Sun, B.; Gates, R.N.; Chang, P. 1993: Normocalcemic blood or crystalloid cardioplegia provides better neonatal myocardial protection than does low-calcium cardioplegia Journal of Thoracic and Cardiovascular Surgery 105(2): 201-206
Kacila, M.; Granov, N.; Straus, S.; Omerbasić, E.; Saefer, K.; Donlić, E. 2006: Antegrade warm blood cardioplegia compared to crystalloid cardioplegia in myocardial protection Medicinski Arhiv 60(5): 294-295
Gerola, L.R.; Oliveira, S.A.; Moreira, L.F.; Dallan, L.A.; Delgado, P.; da Luz, P.L.; Jatene, A.D. 1993: Blood cardioplegia with warm reperfusion versus intermittent aortic crossclamping in myocardial revascularization. Randomized controlled trial Journal of Thoracic and Cardiovascular Surgery 106(3): 491-496
Bar-El, Y.; Kophit, A.; Cohen, O.; Kertzman, V.; Milo, S. 2003: Minimal dissection and continuous retrograde cardioplegia for aortic valve replacement in patients with a patent left internal mammary artery bypass graft Journal of Heart Valve Disease 12(4): 454-457
Follette, D.M.; Steed, D.L.; Foglia, R.; Fey, K.; Buckberg, G.D. 1978: Advantages of intermittent blood cardioplegia over intermittent ischemia during prolonged hypothermic aortic clamping Circulation 58(3 Part 2): I200-I209
No, H.; Nishida, S.; Takagi, T.; Mohri, R. 2016: Thoracic Endovascular Aortic Aneurysm Repair in a Young Patient with Descending Aortic Injury;Report of a Case Kyobu Geka. Japanese Journal of Thoracic Surgery 69(9): 783-786
Burris, N.S.; Dyverfeldt, P.; Hope, M.D. 2016: Ascending Aortic Stiffness with Bicuspid Aortic Valve is Variable and Not Predicted by Conventional Parameters in Young Patients Journal of Heart Valve Disease 25(3): 270-280