Impedance of the arterial system and cardiac activity
Karpman, V.L.; Orel, V.R.
Human Physiology 11(4): 274-278
1985
ISSN/ISBN: 0362-1197 PMID: 3830866 Document Number: 253678
The input impedance of the arterial system was studied in healthy people at rest and during physical load and in hypertensive patients. A mathematical model of equivalent input resistance was developed. This method makes it possible to analyze developmental mechanisms of hypertension under normal and pathological conditions and to assess the loads of left ventricle contractility regimes.
Document emailed within 1 workday
Related Documents
Concu, A.; Scorcu, M.; Marcello, C.; Rocchitta, A.; Molari, A.; Esposito, A.; Orani, G. 1990: Unchanging cardiac activity while increasing respiratory activity at the start of exercise in man: a beat-by-beat analysis by means of the impedance cardiography method Cardiologia 35(10): 845-850Thayer, J.F.; Uijtdehaage, S.H. 2001: Derivation of chronotropic indices of autonomic nervous system activity using impedance cardiography Biomedical Sciences Instrumentation 37: 331-336
Shimizu, H.; Seki, S.; Mizuguchi, A.; Tsuchida, H.; Watanabe, H.; Namiki, A. 1990: Cardiac output monitoring by impedance cardiography in cardiac surgery Masui. Japanese Journal of Anesthesiology 39(4): 508-512
Savina, L.A. 1994: Age-related dynamics of effectors of the arterial basin system in people with deviations in the activity of the cardiovascular system of the ischemic type Fiziologiia Cheloveka 20(5): 61-65
Lin, C.I.; Wu, S.L.; Tao, P.L.; Chen, H.M.; Wei, J. 1993: The role of cyclic AMP and phosphodiesterase activity in the mechanism of action of tetramethylpyrazine on human and dog cardiac and dog coronary arterial tissues Journal of Pharmacy and Pharmacology 45(11): 963-966
Siebert, J. 1990: Use of impedance plethysmography in the studies of cardiac function Przeglad Lekarski 47(4): 412-415
Banovic, M.; Brkovic, V.; Vujisic-Tesic, B.; Nedeljkovic, I.; Trifunovic, D.; Ristic, A.; Nikolic, S. 2015: Valvulo-arterial impedance is the best mortality predictor in asymptomatic aortic stenosis patients Journal of Heart Valve Disease 24(2): 156-163
Sitnikova, M.I. 1991: The activity of the components of the kinin system in renal vein blood in vasorenal arterial hypertension Terapevticheskii Arkhiv 63(12): 42-46
Marshall, M.; Weithmann, K.U.; Sacher, D. 1986: Topographic aspects of prostacyclin-like and fibrinolytic activity and of biogenic amines in the arterial system of the mini-pig Wiener Klinische Wochenschrift 98(7): 215-217
Adamicza, A.; Tutsek, L.; Daróczy, B.; Bari, F.; Nagy, S. 1994: The measurement of cardiac output in dogs by impedance cardiography with different electrode arrangements Acta Physiologica Hungarica 82(1): 37-52
Hiltmann, W.D.; Kollmeier, W.; Stegaru, W.; Schaumann, H.J. 1974: Comparative studies on cardiac volume using impedance cardiography and invasive methods Verhandlungen der Deutschen Gesellschaft für Innere Medizin 80: 1181-1183
Zhang, Q. 1984: Study on the cardiac function of normal residents at an altitude of 2,300 m by impedance plethysmocardiography Zhonghua Xin Xue Guan Bing Za Zhi 12(2): 111-113
Yamaguchi, H.; Yamauchi, H.; Hazama, S.; Hamamoto, H. 2000: Evaluation of body fluid status after cardiac surgery using bioelectrical impedance analysis Journal of Cardiovascular Surgery 41(4): 559-566
Newman, D.G.; Callister, R. 1999: The non-invasive assessment of stroke volume and cardiac output by impedance cardiography: a review Aviation Space and Environmental Medicine 70(8): 780-789
Draganov, V. 1982: Impedance cardiographic evaluation of cardiac function in patients with ischemic heart disease Vutreshni Bolesti 21(2): 121-125
Smirnov, V.M.; Lychkova, A.E. 2002: Mechanism of synergism of the sympathetic and parasympathetic nervous system in regulating cardiac and gastric activity Vestnik Rossiiskoi Akademii Meditsinskikh Nauk 4: 16-20
Kolber-Postepska, B.; Zebrowska-Lupina, I.; Markiewicz, M.; Horubała-Bielak, G. 1989: Effect of captopril on various components of the kinin system and plasma renin activity in patients with idiopathic arterial hypertension Kardiologia Polska 32(3): 121-130
Kiesler, T.W.; Voorhees, W.D.; Wessale, J.L.; Pham, C.K. 1990: Impedance cardiography by use of a spot-electrode array to track changes in cardiac output in anesthetized dogs Journal of the American Veterinary Medical Association 196(11): 1804-1810
Lage, S.G.; Santello, J.L.; Ramires, J.A.; Bellotti, G.; Pileggi, F. 1987: Comparison between biothoracic impedance and thermodilution for the determination of cardiac output in patients with heart diseases Arquivos Brasileiros de Cardiologia 49(4): 229-234
Segard, M.; Tom, J.; Carey, P.; Fronek, A. 1985: Irrigraphy (impedance plethysmography), segmental blood pressure and Doppler velocity metering in the assessment of arterial occlusive disease Journal des Maladies Vasculaires 10(3): 227-233