A new process of valve replacement: autografts of fascialata
Michaud, P.; Chassignolle, J.; Termet, H.; Rassat, J.P.; Dureau, G.; Du Grès, B.; Teneriello, F.
Lyon Chirurgical 66(3): 228-229
1970
ISSN/ISBN: 0024-7782 PMID: 5429804 Document Number: 20863
Document emailed within 1 workday
Related Documents
Remadi, J.P.; Duveau, D. 2004: Long-term results of mechanical valve replacement: isolated mitral valve replacement and mitral-aortic valve replacement Journal of Heart Valve Disease 13(Suppl 1): S26Takemura, T.; Shimamura, Y.; Sakaguchi, M.; Tsuda, Y.; Iwasa, S. 2003: Aortic valve replacement with a freestyle stentless valve using the modified subcoronary technique and hemiarch replacement for bicuspid aortic valve and ascending aortic aneurysma; report of a case Kyobu Geka. Japanese Journal of Thoracic Surgery 56(5): 411-413
Okita, Y.; Miki, S.; Kusuhara, K.; Ueda, Y.; Tahata, T.; Yamanaka, K.; Higa, T. 1992: Analysis of left ventricular motion after mitral valve replacement with a technique of preservation of all chordae tendineae. Comparison with conventional mitral valve replacement or mitral valve repair Journal of Thoracic and Cardiovascular Surgery 104(3): 786-795
Tateishi, M.; Koide, M.; Kunii, Y.; Watanabe, K.; Ohsawa, M. 2006: Valve-in-valve replacement of primary tissue valve failure of bovine pericardial valve minor Kyobu Geka. Japanese Journal of Thoracic Surgery 59(1): 61-64
Garg, A.; Rao, S.V.; Visveswaran, G.; Agrawal, S.; Sharma, A.; Garg, L.; Mahata, I.; Garg, J.; Singal, D.; Cohen, M.; Kostis, J.B. 2017: Transcatheter Aortic Valve Replacement Versus Surgical Valve Replacement in Low-Intermediate Surgical Risk Patients: a Systematic Review and Meta-Analysis Journal of Invasive Cardiology 29(6): 209-216
Wu, Z.K.; Sun, P.W.; Zhang, X.; Zhong, F.T.; Tong, C.W.; Lu, K. 2000: Superiority of mitral valve replacement with preservation of subvalvular structure to conventional replacement in severe rheumatic mitral valve disease: a modified technique and results of one-year follow up Journal of Heart Valve Disease 9(5): 616-622
Mori, T.; Kitamura, S.; Verruno, E.; Kenaan, G.; Kay, J.H. 1974: Tricuspid valve replacement. a comparative experimental study with Starr-Edwards ball valve, Beall disc valve, and Kay-Shiley disc valve with muscle guard Journal of Thoracic and Cardiovascular Surgery 68(1): 30-36
Ohtsubo, S.; Sakurai, J.; Suda, H.; Ohteki, H.; Itoh, T. 1991: Marfan's syndrome with annulo-aortic ectasia and ruptured mitral chorda--a case report of combined composite valve graft replacement of the aortic root and mitral valve replacement Nihon Kyobu Geka Gakkai 39(11): 2096-2101
Habib, G.; Ferracci, A.; Garcia, M.; Ambrosi, P.; Riberi, A.; Kreitmann, B.; Métras, D.; Luccioni, R. 1996: Value of echocardiography in the study of aortic valve homografts and autografts Archives des Maladies du Coeur et des Vaisseaux 89(10): 1267-1276
Minami, K.; Ohlmeier, H.; Körner, M.M.; Gleichmann, U.; Körfer, R. 1987: Long-term results following heart valve replacement with the Omniscience prosthesis: can heart valve replacement with this prosthesis be recommended? Helvetica Chirurgica Acta 54(3): 267-275
Wariishi, S.; Kanemitsu, N.; Okabe, M.; Nakamura, T.; Kitamura, F. 2000: Aortic valve replacement for aortic valve stenosis due to congenital bicuspid aortic valve with abnormal positioning of coronary orifice, pseudotendon, and persistent left superior vena cava, report of a case Kyobu Geka. Japanese Journal of Thoracic Surgery 53(7): 586-589
Sato, T.; Isomura, T.; Suma, H.; Horii, T.; Kobashi, T.; Kanemitsu, H. 2000: Aortic valve/root replacement using a stentless bioprosthesis (Medtronic Freestyle valve) Kyobu Geka. Japanese Journal of Thoracic Surgery 53(4): 301-304
Suma, K.; Takeuchi, Y.; Inoue, K.; Shiroma, K.; Koyama, Y.; Narumi, J.; Kaneko, H.; Nishiyama, K.; Tsuji, T.; Kotsuka, H. 1985: Clinical results of the Starr-Edwards ball valve for mitral valve replacement Kyobu Geka. Japanese Journal of Thoracic Surgery 38(3): 171-179
1970: Prosthetic heart valve replacement, with special reference to the ball type valve Kyobu Geka. Japanese Journal of Thoracic Surgery 23(1): 71-73
Pluth, J.R.; Broadbent, J.C.; Danielson, G.K. 1973: Aortic and mitral valve replacement with the cloth-covered Braunwald-Cutter valve Mayo Clinic Proceedings 48(10): 722-727
Santibáñez Salgado, J.A.; Celaya Lara, S.; Urrea Ramos, M.S.; Ono Okabe, S.; Herrera Alarcón, V. 1994: Mitral valve replacement by mechanical disk valve. a surgical alternative Archivos del Instituto de Cardiologia de Mexico 64(2): 197-203
Nakano, K.; Koyanagi, H.; Hashimoto, A.; Ohtsuka, G.; Nojiri, C. 1994: Tricuspid valve replacement with the bileaflet St. Jude Medical valve prosthesis Journal of Thoracic and Cardiovascular Surgery 108(5): 888-892
Ostrowski, S.ła.; Zasłonka, J.; Walczak, A.; Stefaniak, B.; Jaszewski, R.; Jander, S.ła.; Iwaszkiewicz, A. 2004: Tricuspid valve surgery secondary to mitral and aortal valve replacement Kardiologia Polska 60(Suppl 1): i
Perier, P.; Bessou, J.P.; Swanson, J.S.; Bensasson, D.; Chachques, J.C.; Chauvaud, S.; Deloche, A.; Fabiani, J.N.; Blondeau, P.; d'Allaines, C. 1985: Comparative evaluation of aortic valve replacement with Starr, Björk, and porcine valve prostheses Circulation 72(3 Part 2): Ii140-Ii145
Yamashita, M.; Saigenji, H.; Shimokawa, S.; Arikawa, K.; Morishita, Y.; Taira, A. 1986: Severe mechanical hemolysis after valve replacement with St. Jude Medical valve--a report of five cases Nihon Kyobu Geka Gakkai 34(12): 2142-2146