Abnormally high values for direct bilirubin in serum as measured with the Technicon SMAC
Vasiliades, J.; Monaco, S.; Miller, P.; Lauer, J.
Clinical Chemistry 29(9): 1691
1983
ISSN/ISBN: 0009-9147 PMID: 6883685 Document Number: 207356
Document emailed within 1 workday
Related Documents
Furda, J.; Morgenstern, S.; Snyder, L.R. 1976: Derivatives of 1-naphthyl ethylenediamine dihydrochloride for standardization of direct-bilirubin assays done with the Technicon "SMAC" Clinical Chemistry 22(7): 1042-1046Whitlow, K.J.; Gochman, N.; Zettner, A. 1980: Potential bilirubin interference with the Technicon SMAC alkaline phosphatase activity measurement Clinical Chemistry 26(2): 359-360
Brown, S.; Miller, W.G. 1990: Determination of magnesium in serum by the technicon SMAC with a calmagite method with blank correction Clinical Chemistry 36(11): 1990-1991
David, R.M.; Shihabi, Z.K. 1984: Diluent in the technicon SMAC assay for iron modified to avoid serum precipitation Clinical Chemistry 30(4): 579
Harrison, S.P.; Barlow, I.M.; Hogg, G.L. 1988: Technicon "CHEM 1" direct bilirubin assay evaluated Clinical Chemistry 34(10): 2162
Chan, K.M.; Koenig, J.; Calvin, D.; Stahlschmidt, G.; McClellan, A.C.; Skogen, W.; Landt, M. 1987: Cobas-Bio and Technicon RA-1000 assays of direct bilirubin compared Clinical Chemistry 33(9): 1670-1671
Bavinton, P.R.; Vaughan, N.M.; Johnston, C.J.; Lea, L. 1977: Analysis of urine with the Technicon SMAC Clinical Chemistry 23(10): 1940
O'Leary, N.; Duggan, P.F. 1980: Some improvements in operation of the Technicon SMAC system Clinical Chemistry 26(6): 793
Ahlfors, C.E. 1981: Effect of serum dilution on apparent unbound bilirubin concentration as measured by the peroxidase method Clinical Chemistry 27(5): 692-696
Manuel Echeverría, J.; Jiménez Jiménez, J.; Lozano, C.H.; Lara Vals, L. 1979: Capillary and central serum bilirubin: reliability of values Boletin Medico del Hospital Infantil de Mexico 36(3): 475-480
Owa, J.A. 1988: Relationship between values of serum bilirubin as determined by two methods: implications for the management of neonatal jaundice East African Medical Journal 65(2): 92-98
Robertson, E.A.; Wright, E.; Chesler, R.A.; Elin, R.J. 1982: Lactate dehydrogenase activity as measured by the SMAC is related to flow-cell energy Clinical Chemistry 28(10): 2106-2109
Onishi, S.; Itoh, S. 1983: Clinical significance of the panic values in emergency laboratory tests--the panic value of serum bilirubin Rinsho Byori. Japanese Journal of Clinical Pathology 31 Suppl: 129-144
Macart, M.; Dupond, L. 1994: A stable and high-titre reference serum for bilirubin assay Annales de Biologie Clinique 52(5): 387
Bausserman, L.L.; Saritelli, A.L.; Milosavljevic, D. 1994: High-density lipoprotein subfractions measured in stored serum Clinical Chemistry 40(9): 1713-1716
Franzini, C.; Cattozzo, G. 1987: Caffeine-splitting of bilirubin/albumin complex: its relevance to the spectrophotometry of bilirubin in serum Clinical Chemistry 33(4): 597-599
Sanpavat, S.; Nuchprayoon, I. 2004: Noninvasive transcutaneous bilirubin as a screening test to identify the need for serum bilirubin assessment Journal of the Medical Association of Thailand 87(10): 1193-1198
Kapitulnik, J.; Kaufmann, N.A.; Alayoff, A.; Blondheim, S.H. 1976: Characteristics of a photoproduct of bilirubin found in vitro and in vivo, and its effect on the bilirubin binding affinity of serum Birth Defects Original Article Series 12(2): 53-60
Grgicević, D. 1983: The effect of long-term plasmapheresis on the composition of blood. III. Changes in the concentration of total, direct and indirect bilirubin, alkaline phosphatase, serum transaminases (SGOT, SGPT). total lipids, triglycerides and cholesterol Bilten Za Hematologiju i Transfuziju 11(2-3): 39-50
Leslie, G.I.; Philips, J.B.; Cassady, G. 1987: Capillary and venous bilirubin values. Are they really different? American Journal of Diseases of Children 141(11): 1199-1200