Method of preventing ptosis and repositioning of the prolapsed vitreous body during intraocular operations
Brovkina, A.F.; Movshovich, A.I.; Kodzov, M.B.; Batmanov, I.E.
Vestnik Oftalmologii 1983(6): 33-35
1983
ISSN/ISBN: 0042-465X PMID: 6659235 Document Number: 202249
Document emailed within 1 workday
Related Documents
Volkov, V.V.; Mikhaĭlov, A.I. 1973: Removal of intraocular foreign bodies by using a magnet through the vitreous body Oftalmologicheskii Zhurnal 28(6): 424-429Stoffelns, B.; Dick, B.; Pfeiffer, N. 1999: Why implantation of a second intraocular lens after subluxation of the first implanted lens into the vitreous body can be assessed as avoidable malpractice Klinische Monatsblatter für Augenheilkunde 215(1): Aa7-Aa9; Author Reply Aa10
Agafonov, V.A.; Anisimov, S.I.; Fedorov, S.N. 1984: Method of determining the colloidal status of the vitreous body Biulleten' Eksperimental'noi Biologii i Meditsiny 98(12): 761-764
Seo, M.S.; Yoon, K.C.; Yang, K.J.; Park, Y.G. 1998: A new technique for repositioning a posteriorly dislocated intraocular lens Ophthalmic Surgery and Lasers 29(2): 147-150
Tano, Y. 1991: Vitreous surgery for intraocular proliferative disorders Nippon Ganka Gakkai Zasshi 95(5): 405-420
Dralands, L.; Piot, R.; Missotten, L. 1981: Vitreous surgery with perforating eye wounds and intraocular foreign bodies Bulletin de la Societe Belge d'Ophtalmologie 193: 25-30
Wessing, A.; Meyer-Schwickerath, G. 1974: Intraocular Cysticercus and its treatment with a vitreous suction cutter (VISC) Klinische Monatsblatter für Augenheilkunde 165(6): 865-867
Hayashi, H.; Oshima, K. 1984: Effect of vitreous and retinal extract on growth of cultured human intraocular fibroblast Nippon Ganka Gakkai Zasshi 88(6): 940-947
Novak, I.; Davies, P.S.; Elliott, M.J. 1992: Noninvasive estimation of total body water in critically ill children after cardiac operations. Validation of a bioelectric impedance method Journal of Thoracic and Cardiovascular Surgery 104(3): 585-589
Jacob, P.; Thomas, R.; Sen, S.; Raju, R. 1993: Anterior capsular support for posterior chamber intraocular lenses following vitreous loss in endocapsular surgery Indian Journal of Ophthalmology 41(1): 15-16
Braun, C.; Bauer, M.; Rose, S.; Bühren, V. 1992: A simple method for repositioning metatarsal fractures Aktuelle Traumatologie 22(3): 129-131
Szczypiński, J.; Bartkowska-Orlowska, M. 1974: Ultrasonography of the vitreous body Klinika Oczna 14(10): 981-989
Stankiewicz, A. 1976: Physiopathology of the vitreous body Klinika Oczna 46(6): 677-685
Latimer, C.A.; Wyman, M.; Burt, J.K. 1983: Vitreous foreign body Journal of the American Veterinary Medical Association 182(12): 1401-1402
Logaĭ, I.M.; Kryzhanovskaia, T.V. 1984: Intraocular correction in preventing disability from crystalline lens injury Oftalmologicheskii Zhurnal 1984(4): 205-207
Khiva, A.S. 1983: Timolol maleate in preventing postoperative increase of intraocular pressure Vestnik Oftalmologii 1983(4): 22-24
Medvetskaia, G.A.; Golychev, V.N. 1995: Results of the treatment of congenital ptosis in children using the Friedenwald-Guyton method Vestnik Oftalmologii 111(1): 35
Shershevskaia, S.F.; Eremenko, A.I. 1980: Changes in the vitreous body in retinal pigment dystrophy Oftalmologicheskii Zhurnal 35(8): 461-463
Iwaszkiewicz-Bilikiewiczowa, B.; Janukowiczowa, H.; Adamczewska, I. 1976: Argon laser photocoagulation of changes in the vitreous body Klinika Oczna 46(11): 1299-1304
Agafonov, V.A.; Anisimov, S.I. 1986: Adhesion of the vitreous body to cured polymers Biulleten' Eksperimental'noi Biologii i Meditsiny 101(3): 370-372