Steam sterilization of rubber closures in sealed nylon bags
Butler, L.D.; Haydu, E.J.; Chrai, S.
Journal of Parenteral Science and Technology a Publication of the Parenteral Drug Association 36(3): 99-101
1982
ISSN/ISBN: 0279-7976 PMID: 7097459 Document Number: 194167
A process was developed for sterilizing rubber closures in sealed double nylon bags fitted with Nomex breather strips. The sterilization cycle parameters were determined by monitoring heat penetration during autoclaving and correlating the temperature data with biological impact through the use of spore strips and stoppers contaminated with spore suspension. Other variables of importance to the process are the width of the breather strip, the number of stoppers in the bag and the method of placing the filled bags on pallets for autoclaving.