Percutaneous removal of intravascular fragments from infusion, angiography and cerebrospinal fluid drainage catheters with the loop-snare technic

Weber, J.; Sartor, K.

Der Chirurg; Zeitschrift für Alle Gebiete der Operativen Medizen 51(11): 711-716

1980


ISSN/ISBN: 0009-4722
PMID: 7471940
Document Number: 167339
Intravascular loss of catheter fragments (for infusion, angiographic, or CSF shunting purposes) represents a serious complication. There is a high morbidity rate and even mortality when the foreign body remains within the vascular system. Nonsurgical percutaneous removal of 16 catheter fragments from the venous side and 1 Gianturco coil from the abdominal aorta by use of a catheter sheath introducer system and the loop-snare technique is reported. If there is no local thrombosis, fragment recovery is relatively easy. Surgical intervention should be resorted to only when percutaneous removal turns out to be impossible.