"Dinamap"--a new automatic indirect blood pressure registration device for anaesthetized patients
Stoffregen, J.
Der Anaesthesist 29(9): 517-518
1980
ISSN/ISBN: 0003-2417 PMID: 7468995 Document Number: 160746
The "Dinamap" measures automatically using a non invasive technique the arterial systolic, diastolic and mean pressure and the pulse rate. Its accuracy is comparable with invasive transducer monitoring. The device is automatically zero-controlled and is based on the oscillometric procedure. The interval can be selected within a wide range.
Document emailed within 1 workday
Related Documents
Meyer-Sabellek, W.; Schulte, K.L.; Distler, A.; Gotzen, R. 1987: Indirect ambulatory, automatic 24 h blood pressure determination: possibilities and limits Verhandlungen der Deutschen Gesellschaft für Innere Medizin 93: 284-292Bock, K.D.; Anlauf, M. 1978: Automatic apparatus for indirect blood pressure measurement. Progress or business? Münchener Medizinische Wochenschrift 120(23): 787-788
Netea, R.T.; Smits, P.; Thien, T. 1995: Accuracy of an automatic blood pressure device: the Omron HEM403C Journal of Human Hypertension 9(9): 783-784
Sheps, S.G.; Elveback, L.R.; Close, E.L.; Kleven, M.K.; Bissen, C. 1981: Evaluation of the Del Mar Avionics automatic ambulatory blood pressure-recording device Mayo Clinic Proceedings 56(12): 740-743
Harioka, T.; Nomura, K.; Ito, T. 1994: Clinical evaluation of the Terumo ES H51 semi-automatic blood pressure measuring device Masui. Japanese Journal of Anesthesiology 43(12): 1906-1909
Roy, R.C.; Morgan, L.; Beamer, D. 1983: Factitiously low blood pressure from the Dinamap Anesthesiology 59(3): 258-259
Maines, J.G. 1988: DINAMAP blood pressure monitor Journal of Family Practice 27(4): 357 360
Bertram, B.; von Wallenberg, E.L.; Meyer-Erkelenz, J.D. 1981: Automatic indirect measurement of blood pressure in resting and exercising subjects: analysis of the Korotkov sound pattern; variable "time gate" for artifact suppression Biomedizinische Technik. Biomedical Engineering 26(4): 81-84
Braun, H.J.; Rabouw, H.; Werner, H.; van Montfrans, G.A.; de Stigter, C.; Zwinderman, A.H. 1999: Measurements of blood pressure with various techniques in daily practice: uncertainty in diagnosing office hypertension with short-term in-hospital registration of blood pressure Blood Pressure Monitoring 4(2): 59-64
Zwirn, P.; Burnet, H.; Barthélémy, P. 1991: Comparison between left and right humeral arterial pressure. Indirect measurement with an automatic apparatus Annales de Cardiologie et d'Angeiologie 40(4): 203-208
Tsukatani, H.; Yamada, S.; Fukuzawa, K.; Hamaguchi, C. 1979: Effect of lysolecithin on the systemic arterial blood pressure of anaesthetized rats Journal of Pharmacy and Pharmacology 31(2): 110-111
Papadopoulos, G.; Vescio, G.; Mieke, S. 1993: Does the photoplethysmographic technique show an improvement in the measurement of the indirect blood pressure in intensive care patients? Der Anaesthesist 42(1): 23-28
Shearman, C.P.; Simms, M.H. 1988: Ankle blood pressure measured by automatic oscillotonometry: a comparison with Doppler pressure measurements Annals of the Royal College of Surgeons of England 70(4): 257
Parsons, D.; Convertino, V.; Idris, A.; Smith, S.; Lindstrom, D.; Parquette, B.; Aufderheide, T. 2009: The impedance threshold device (ITD-7)--a new device for combat casualty care to augment circulation and blood pressure in hypotensive spontaneously breathing warfighters Journal of Special Operations Medicine: a Peer Reviewed Journal for Sof Medical Professionals 9(2): 49-53
Bottini, P.B.; Carr, A.A.; Rhoades, R.B.; Prisant, L.M. 1992: Variability of indirect methods used to determine blood pressure. Office vs mean 24-hour automated blood pressures Archives of Internal Medicine 152(1): 139-144
Schoknecht, G. 1973: Standardization of automatic blood-pressure measurements Biomedizinische Technik. Biomedical Engineering 18(5): 188-191
Alsner, T.; Kann, T. 1975: Non-invasive automatic measurement of blood pressure Ugeskrift for Laeger 137(14): 780-783
Sundberg, S.; Gordin, A. 1988: Continuous indirect measurement of blood pressure Duodecim; Laaketieteellinen Aikakauskirja 104(9): 690-699
Adorjani, C.; Siegenthaler, W.; Vetter, W. 1979: Are automatic devices suitable for blood pressure determinations? Schweizerische Medizinische Wochenschrift 109(33): 1225-1230
Frandsen, F. 1993: Automatic blood pressure monitoring during exercise test Ugeskrift for Laeger 155(28): 2217-2218