Removal of a knotted flow-directed catheter by a nonsurgical method
Kumar, S.P.; Yans, J.; Kwatra, M.; Loesch, D.M.; Viturawong, V.
Annals of Internal Medicine 92(5): 639-640
1980
ISSN/ISBN: 0003-4819 PMID: 7387009 Document Number: 154278
Document emailed within 1 workday
Related Documents
Al-Kayed, O.; Al-Bouti, F.; Ababneh, M.O. 2008: Surgical removal of a looped and knotted epidural catheter in a postpartum patient--a case report Middle East Journal of Anaesthesiology 19(4): 913-918Hoskinson, J.J.; Wooten, P.; Evans, R. 1991: Nonsurgical removal of a catheter embolus from the heart of a foal Journal of the American Veterinary Medical Association 199(2): 233-235
Tanaka, M.; Tsuchioka, H.; Abe, T.; Shimizu, T.; Washizu, T.; Murase, M.; Nogaki, H.; Sugiyama, N.; Takeuchi, E.; Kakihara, R.; Kito, S.; Suenaga, Y.; Watanabe, T.; Iyomasa, Y. 1980: Nonsurgical technic for removal of a fragmented catheter from the pulmonary artery Nihon Kyobu Geka Gakkai 28(8): 1310-1315
Petrilli, G.; Peranzoni, P.F.; Barbieri, E. 1992: A nonsurgical technique for removal of a Swan-Ganz catheter entrapped in the right atrium Journal of Cardiovascular Surgery 33(2): 251-252
Berkowitz, R.L.; Rafferty, T.D. 1980: Pulmonary artery flow-directed catheter use in the obstetric patient Obstetrics and Gynecology 55(4): 507-511
Carl, P.; Kruse, L.; Bach, V.; Crawford, M.E.; Ravlo, O. 1983: Knotted epidural catheter Ugeskrift for Laeger 145(40): 3103-3104
Van Rooij, W.J.; den Heeten, G.J. 1993: Digital lung angiography using a flow-directed balloon catheter in the diagnosis of pulmonary embolisms Nederlands Tijdschrift Voor Geneeskunde 137(30): 1492-1498
Franz, C.; Mennicken, U. 1978: Antegrade catheterization of the aorta with a flow-directed balloon catheter following transseptal left atrial puncture: a new technique Zeitschrift für Kardiologie 67(9): 645-648
Kimura, K.; Tanaka, N. 1982: The significance of bed-side right cardiac catheterization using Swan-Ganz flow-directed catheter--pulmonary hemodynamic profiles of respiratory failure patients under mechanical ventilatory assistance Nihon Kyobu Shikkan Gakkai Zasshi 20(1): 13-19
Fernández, O.Ricardo.; Wuilloud, R.G.; de Wuilloud, J.C.A.; Olsina, R.A.; Martinez, L.D. 2002: On-line preconcentration and determination of cadmium in honey using knotted reactor coupled to flow injection-flame atomic absorption spectrometry Journal - Association of Official Analytical Chemists 85(6): 1410-1414
Pohlenz, O.; Weber, J. 1974: Nonsurgical removal of intraoperative residual calculi from the biliary ducts Der Chirurg; Zeitschrift für Alle Gebiete der Operativen Medizen 45(9): 425-429
Okamoto, M.; Hashimoto, M.; Sueda, T.; Yamada, T. 1994: Coronary flow velocity measurement by intravascular Doppler method--Doppler catheter and Doppler guidewire Nihon Rinsho. Japanese Journal of Clinical Medicine 52 Suppl (Part 1): 394-399
Raju, S.; Fountain, T.; McPherson, S.H. 1998: Catheter-directed thrombolysis for deep venous thrombosis Journal of the Mississippi State Medical Association 39(3): 81-84
Jones, R.G.; Gardner, G.P.; Morris, M.E. 2012: Catheter-directed thrombolysis in a patient with purpura fulminans American Surgeon 78(11): E448-E449
Pagé, D.E.; Turpin, C. 2000: A simple and inexpensive method of subcutaneous implantation of catheter distal segment using a Tenckhoff curled catheter Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis 20(1): 85-87
Kandarpa, K. 1999: Catheter-directed thrombolysis of peripheral arterial occlusions and deep vein thrombosis Thrombosis and Haemostasis 82(2): 987-996
Heymans, S.; Verhaeghe, R.; Stockx, L.; Collen, D. 1998: Feasibility study of catheter-directed thrombolysis with recombinant staphylokinase in deep venous thrombosis Thrombosis and Haemostasis 79(3): 517-519
Gobbi, P. 2001: Should bladder training be done before catheter removal? Assistenza Infermieristica e Ricerca: Air 20(3): 140-141
Klement, W.; Rothe, G.; Peters, J. 1991: Paraplegia following removal of an epidural catheter Regional-Anaesthesie 14(5): 88-91
Stejfa, M.; Vítovec, J.; Studeník, P.; Roubalík, P. 1987: Flow-directed catheters--pros and cons Vnitrni Lekarstvi 33(5): 497-501