Critical analysis of the effectiveness of secondary prevention of occupational hearing loss

Hétu, R.

Journal of Occupational Medicine. Official Publication of the Industrial Medical Association 21(4): 251-254

1979


ISSN/ISBN: 0096-1736
PMID: 438914
Document Number: 153140
There is an unavoidable error margin associated with audiometric measurements. This error margin was used to set specificity and sensitivity criteria for repeated testing of hearing. The criteria were applied to the time growth function of occupational hearing loss for typical noise exposures. It is shown that monitoring audiometry can be an effective screening procedure only for the first five to ten years of exposure to a given noise environment. A strategy for effective secondary prevention of occupational hearing loss is outlined.