Preliminary observations on the detection of endotoxins in drinking water

Bucci, G.; Tieghi, A.; Zanforlini, B.

Bollettino dell'Istituto Sieroterapico Milanese 58(5): 387-390

1979


ISSN/ISBN: 0021-2547
PMID: 553519
Document Number: 142093
3 samples of water of the Po river at different steps of the treatment of purification were examined with LAL test. 32 ng/ml of endotoxin were detected in potable water.