Haemodynamics of cardiac tamponade during various modes of ventilation

Möller, C.T.; Schoonbee, C.G.; Rosendorff, C.

British Journal of Anaesthesia 51(5): 409-415

1979


ISSN/ISBN: 0007-0912
PMID: 109108
Document Number: 140977
Cardiac output and pleural, pericardial, arterial and cardiac pressures were measured in baboons Papio ursinus during different modes of ventilation in the presence of acute cardiac tamponade. Fluctuations in pleural pressure during intermittent positive pressure ventilation were transmitted to the pericardial fluid. Cardiac output and transmural right ventricular end-diastolic pressure were significantly greater during spontaneous ventilation than during intermittent positive pressure ventilation with or without positive end-expiratory pressure. Patients undergoing surgery for cardiac tamponade should be allowed to breathe spontaneously until the chest is opened and the pericardium incised.

Document emailed within 1 workday
Secure & encrypted payments