Continuous traction method in the removal of infected endocardial pacemaker electrode
Yokoyama, S.; Nobuoka, W.; Konishi, M.; Asazuma, S.; Tani, T.; Une, I.
Kyobu Geka. Japanese Journal of Thoracic Surgery 3: 180-182
1979
ISSN/ISBN: 0021-5252 PMID: 430902 Document Number: 140915
Document emailed within 1 workday
Related Documents
Lee, M.E.; Chaux, A.; Matloff, J.M. 1977: Avulsion of a tricuspid valve leaflet during traction on an infected, entrapped endocardial pacemaker electrode. the role of electrode design Journal of Thoracic and Cardiovascular Surgery 74(3): 433-435Rényi-Vámos, F.; Bodor, E.; Moravcsik, E.; Gyöngy, T.; Kalmár, I.; Szabó, Z. 1979: Removal of the electrode of an infected pacemaker by using extracorporeal perfusion Orvosi Hetilap 120(41): 2495-2496
Nakata, T.; Yamamoto, T.; Hamada, T.; Kashu, Y.; Takahashi, H.; Sato, M.; Watanabe, Y.; Sato, N.; Kawachi, K. 1998: Successful removal of an infected pacemaker electrode adhered to the tricuspid valve Kyobu Geka. Japanese Journal of Thoracic Surgery 51(9): 765-768
Das, P.B.; McArthur, J.D.; Gupta, R.P.; Jairaj, P.S.; John, S. 1974: Migration of retained endocardial pacemaker electrode and its management Indian Heart Journal 26(3): 198-201
Grosse-Heitmeyer, W.; Most, E.; Müller, U.S.; Bender, F. 1982: Transvenous retrieval of endocardial pacemaker electrode fragments Herz 7(3): 198-201
Mizuno, A.; Kurosawa, H.; Wakabayashi, K.; Suzuki, K.; Mashiko, K.; Nakano, M.; Saitoh, F. 1993: Extraction of infected pacemaker electrode using catheter and snare Kyobu Geka. Japanese Journal of Thoracic Surgery 46(11): 937-940
Saab, S.B.; Jung, J.Y.; Almond, C.H. 1977: Retention of pacemaker electrode complicated by Serratia marcescens septicemia. Removal with total cardiopulmonary bypass Journal of Thoracic and Cardiovascular Surgery 73(3): 404-407
Thiele, G.; Lachmann, W.; Bredel, P.; Daniel, E. 1985: Extraction of the electrodes by continuous traction--an effective procedure in treating pacemaker wearers with secondary inflammatory complications Zeitschrift für die Gesamte Innere Medizin und ihre Grenzgebiete 40(24): 705-707
Fishbane, B.M.; Riley, L.H. 1976: Continuous trans-physeal traction: a simple method of bone lengthening Johns Hopkins Medical Journal 138(3): 79-81
Grigorov, S.S.; Frolov, V.M.; Votchal, F.B. 1983: Puncture method of implanting endocardial electrodes for continuous electric stimulation of the heart Grudnaia Khirurgiia 5: 68-72
Faber, T.S.; Grom, A.; Zehender, M. 2003: A unique pacemaker complication of thrombus formation in the right internal jugular vein due to unusual migration of an atrial pacemaker electrode Journal of Invasive Cardiology 15(7): 423-425
Nishimoto, M.; Hasegawa, S.; Morimoto, T.; Asada, K.; Sasaki, S. 1999: Surgical treatment of septicemia after pacemaker implantation: a case report of removal of infected lead under median sternotomy Kyobu Geka. Japanese Journal of Thoracic Surgery 52(13): 1128-1131
Gorlianskiĭ, P.I. 1975: Use of muscle relaxants of the aconite group in the treatment of fractures and fractures-dislocations of the bones of the limbs by the method of continuous traction Klinicheskaia Khirurgiia 7: 64-65
Mlinarić, I.; Sjerobabski, V.; Stritof, K.; Gjurović, J.; Rudar, M. 1978: Advantages and hazards of the intraoperative control of endocardial electrode pacemakers Acta Chirurgica Iugoslavica 25(1): 87-93
Udall, J.A. 1971: Cardiac pacing by means of an attached endocardial electrode: a case report Current Therapeutic Research 13(10): 660-665
Machejek, J.; Lelakowski, J.; Bednarek, J.; Małecka, B. 2004: Acute pacing parameters of endocardial ventricular leads: comparison of two electrode designs Kardiologia Polska 61(Suppl 2): Ii110-Ii114
Wittenstein, G.J. 1978: The wayward pacemaker electrode Acta Chirurgica Belgica 77(6): 381-387
Neuzner, J.; Pitschner, H.F.; Stöhring, R.; Reinisch, P.; Schlepper, M. 1995: Implantable cardioverter/defibrillators with endocardial electrode systems: long-term stability of the defibrillator's effectiveness Zeitschrift für Kardiologie 84(1): 44-50
Präuer, H.W. 1978: Dislocation and rise of the stimulation threshold in endocardial pacemaker electrodes Die Medizinische Welt 29(19): 799-803
Schulten, H.K.; Grosser, K.D.; Steinbrück, G. 1973: Longtime measurement of stimulus threshold in endocardial pacemaker probes Zeitschrift für Kardiologie 62(7): 617-624