Report on the capsule dosage and mixing system. 3. Suitability testing from a technological and clinical point of view

Welker, D.

Stomatologie der DDR 28(4): 250-258

1978


ISSN/ISBN: 0302-4725
PMID: 274850
Document Number: 133655
The results from experiments with composite filling materials, silicate cements, stone cements, polyacrylate cements, EBA cements and amalgam testify to the suitability of a mixing apparatus already presented (cf. Par II). Apart from industrial predosed products, well known multicomponent materials prepared until now manually, among which Evicrol, were mixed mechanically.