Flexor pollicis longus injury after corrective osteotomy of distal radius malunion with volar fixed-angle plating: case report and review literature of the flexor tendon injuries after volar plating

Kosiyatrakul, A.; Luenam, S.; Prachaporn, S.

Journal of the Medical Association of Thailand 95 Suppl. 10: S213-S218

2012


ISSN/ISBN: 0125-2208
PMID: 23451465
Document Number: 12679
Flexor tendon injury is a potential complication after volar plating of distal radius fracture. This article reports a case of flexor pollicis longus tendon rupture after corrective osteotomy of a distal radius malunion with volar fixed-angle plating. Thirty-three cases of flexor tendon injuries after fixed-angle volar plating and eleven cases of flexor tendon injuries after non-fixed-angle volar plating were also reviewed. The clinical presentation, injured tendons, type of the plate, causes of the injuries and preventions of this complication were discussed.